Aqua PRO APEX Series Owner's Manual - Page 8

Browse online or download pdf Owner's Manual for Water Pump Aqua PRO APEX Series. Aqua PRO APEX Series 20 pages.

Electrical (continued)
APEX Series pumps are factory wired for 230 volt operation. This pump can also be used with 115 volt.
If you have 230 volt motor supply voltage, confirm that the plug is set for 230 volts. The arrow on the plug will point to the 230 volt position.
Refer to the diagram below.
VOLTAGE
SELECTOR
L1
L1
L2
L2
Figure 6 - APEX Series Pump Wiring Diagram
GROUNDING/BONDING
Install, ground, bond and wire motor according to local or National Electrical Code requirements. Permanently ground motor. Use green
ground terminal provided under motor canopy or access plate; use size and type wire required by code. Connect motor ground terminal to
electrical service ground.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the
swimming pool, spa, or hot tub and to all electrical equipment, metal piping or conduit within 5 feet (1.5 m) of the inside walls of swimming
pool, spa, or hot tub.
BONDING
LUG
BONDING
LUG
Figure 7 - DV FLO Pump Bonding Lug Location
Figure 8 - APEX Series Pump Bonding Lug Locations
8