GAS COMBINATION VALVE

1.
Follow pre-maintenance steps on page 4
2.
Remove wiring from combination
valve for thermostat and thermopile
connections (Fig. 11A)
3.
Remove pilot light gas hose connection
(Fig. 11B)
4.
Remove pipe unions from outlet and inlet side of
valve (Fig. 12A & B)
5.
Remove inlet and outlet pipe sections from valve
6.
Installation is reverse of removal with thread
sealant
7.
Check for leaks with leak detection
solution or device
8.
Verify correct manifold pressure during burner
operation, check name plate
THERMOSTAT (200-400°F)
1.
Follow pre-maintenance steps on page 4
2.
Pull thermostat control knob from front of
thermostat, replace control knob if necessary
3.
Remove 2 Phillips screws from the front mounting
bracket (Fig. 13)
4.
Remove wiring from thermostat, note locations to
move to new thermostat
(Fig. 15)
5.
Pry apart holding tongs on the bracket inside the
fryer pot holding the sensing probe. (Fig. 16)
6.
Remove holding nut for thermostat capillary wire
from front side of fryer pot with 18mm wrench (Fig.
14)
7.
Remove thermostat capillary wire and sensing
probe from fryer pot
8.
Installation is reverse of removal, ensure sensing
bulb is mounted in tongs before tightening holding
nut
9.
Use thread sealant on holding nut for capillary wire
and ensure no leaks after install
www.cookingperformancegroup.com
FIG. 11
A
B
FIG. 13
FIG. 15
FIG. 12
A
B
FIG. 14
FIG. 16
7