TROUBLE SHOOTING
PROBLEM
The system fails to start when
vehicle is in reverse gear
The system always detects the
same distance
The system fails to detect obstacles
False alarm
TECHNICAL SPECIFICATIONS
Voltage
Operating temperature
Horizontal detection angle
Detection accuracy
CAUSE
Incorrect connection of power
source
Sensor is likely detecting the ground
Sensors are connected incorrectly
Sensor is likely detecting the ground
9-16VDC
Current
-20° to 70°C
Operating frequency
60°
Vertical detection angle
1cm
Max detection range
Phone 0800 438 862 or 0064 9 476 8052
Web avscarsecurity.com Email
SOLUTION
Check power lead connections and
control module connector (if
applicable)
Check and adjust the vertical angle
of the sensor
Check and reset system e.g. cycle
power
Check and adjust the vertical angle
of the sensor
150mA
315MHz/433MHz
60°
RS4R/RS8 2.5m