CPG 351FEC100B User Manual - Page 5

Browse online or download pdf User Manual for Oven CPG 351FEC100B. CPG 351FEC100B 11 pages. Electric convection ovens

CPG 351FEC100B User Manual
User Manual
351FEC100(B/C/D/E) | 351FEC200(B/C/D/E)K

Startup

Installation
1. Remove packaging before beginning installation.
NOTE:
Some parts are protected with an adhesive film. Remove any glue residue with approved
substances, such as Noble Chemical Strike All Purpose Cleaner (#147STRIKE1G); never use abrasive
substances. (See Cleaning & Maintenance on pg. 11 for our other recommended cleaning agents and
further cleaning instructions)
2. Mount the feet and adjust the height by loosening or tightening each foot to ensure the unit is level.
3. The electrical connections must be close to the equipment and easy to reach.
4. Place the unit under an exhaust hood to ensure you comply with your local regulations.
5. Install the unit at least 2" from the wall and at least 6" from other heat-producing equipment.
Any wall, surface, cabinet, table, etc. in close proximity to the equipment should be made of non-
combustible materials with proper thermal insulation.
6. Law provisions, technical regulations, and directives:
The manufacturer requires the installation to be performed
according to national and local codes and must be performed
by a licensed installer.
7. Checking the functions:
The serial plate, like the example to the right, is located on the
right side panel. Please ensure that the voltage stated on the
serial plate is compatible before performing the electrical connection.
Notes for the Installer
Explain and demonstrate to the user how the equipment works according to the instructions,
and ensure that the user manual is accessible.
Remind the user that any structural alterations or modifications made to the room that houses the
equipment will warrant a recheck of the equipment functions.
Do not install the equipment close to other units that can reach high temperature, as the electrical
components could be damaged. A 6" minimum clearance is required from such equipment.
Electric Connection
The oven must be electrically grounded in accordance with all local and national codes.
(in the USA the National Electrical code ANSI/NFPA no. 70 is applicable).
Exhaust System
The room where the equipment is installed must be fitted with air intakes to guarantee the correct operation of the unit
and air exchange.
During installation, make sure the air suction and evacuation ways are free from any obstacles.
This unit must be installed per all applicable hood regulations.
This unit is not designed to be directly connected to an evacuation duct for the discharge of combustible products.
www.cookingperformancegroup.com
Electric Convection Oven
Item: 351FEC100B
Phase: 1PH
Voltage: 208V, 50/60 Hz
Wattage: 9000W
Lancaster, PA
Serial #:
Conforms to UL STD.197
Certi ed to CSA STD. C22.2 NO. 109
For commercial use only.
MADE IN CHINA
5