CPG 351GUCPG48M User Manual - Page 7
Browse online or download pdf User Manual for Griddle CPG 351GUCPG48M. CPG 351GUCPG48M 15 pages. Electric countertop griddles
User Manual
WARNING:
•
Do not connect to direct current (DC).
•
The installation of the electric griddle should conform to the national electric code and all local
electric codes and ordinances and the local electric company rules and regulations.
•
A qualified electrical installer must install this griddle. Improper installation will void the
manufacturers warrantee.
•
External wiring should be in conduit or an approved type of flexible cable suitable for operation at
the temperature indicated on the wiring diagram, and of a proper size to carry the load.
•
The supply circuit should be properly fused and equipped with a means of disconnecting, as
required by local electrical code.
•
This device should be safely and adequately grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical code, ANSI/NFPA 70, Latest Edition to protect
the user from electrical shock. It requires a grounded system and a dedicated circuit, protected
by a fuse or circuit breaker of proper size and rating. Canadian installation must comply with the
Canadian Electrical Code, CSA C22.2, as applicable.
CONNECTING POWER SUPPLY
NOTE:
Appliances are not internally fused. They must be connected to a suitable disconnect box in
accordance with local code.
NOTE:
CPG Series electric griddles may be wired for operation in the field for either 1-phase or 3-phase
power supplies by making line connections at the junction box(es) located at the rear of the unit.
NOTE:
A qualified electrical installer must install this griddle. Improper installation will void the
manufacturer's warranty.
•
Open cover on junction box at rear of unit.
•
Pigtail leads must be connected to supply power as per the diagrams in this manual.
SUGGESTED WIRE SIZES
NOTE: Use wire size shown or larger (AWG).
208V
Model
1-Phase
351GUCPG24M
#10
351GUCPG36M
#6
351GUCPG48M
#10
www.cookingperformancegroup.com
208V 3-Phase
L1
L2
L3
#16
#12
#16
#12
#12
#12
#6
#6
#8
240V 3-Phase
240V
1-Phase
L1
#8
#14
#6
#10
#8
#6
L2
L3
#10
#14
#10
#10
#6
#8
7