TROUBLESHOOTING
Symptoms
The pilot flame cannot be lit.
The pilot flame is on but the main
burner cannot be lit.
There is a light-back sound when
turning off the gas supply.
Unit has red flame and black smoke.
The issues mentioned above are for reference. If any failure occurs, please stop using and contact
Cooking Performance Group. Safety is first and maintenance should be done after shutting down the
power supply and gas supply.
8
Causes
1. Plug or plug cord of igniter is
damaged.
2. Pressure in the gas pipeline is too low.
3. The pilot nozzle is blocked.
4. Thermocouple connection is loose.
5. The thermocouple is defective.
6. The gas control valve is defective.
1. Pressure in the gas pipeline is too low.
2. Main nozzle is blocked.
3. The gas control valve is defective.
1. Nozzle diameter does not match with
the gas supply.
2. The supply pressure is too low.
3. Flow within the connected pipe is too
low.
1. Nozzle diameter does not match with
the gas supply.
2. Low gas supply.
3. Gas ingredients are volatile in gas
peak period.
1. Replace relevant fittings.
2. Regulate the reducing valve or contact
the gas supplier.
3. Unblock the nozzle.
4. Tighten the thermocouple.
5. Replace the thermocouple.
6. Repair or replace the gas control valve.
1. Regulate the reducing valve or contact
the gas supplier.
2. Unblock the nozzle.
3. Repair or replace the gas control
valve.
1. Regulate the nozzle diameter.
2. Regulate the reducing valve or contact
the gas supplier.
3. Increase the permitted flow.
1. Regulate the nozzle diameter.
2. Increase the gas supply.
3. Decrease the gas flow. Increase it after
the peak.
www.CookingPerformanceGroup.com
Solutions
1-800-678-5517