DG NVMeG4-IP Instructions Manual - Page 13
Browse online or download pdf Instructions Manual for Motherboard DG NVMeG4-IP. DG NVMeG4-IP 16 pages. Nvme ip with pcie gen4 soft ip
dg_nvmeg4ip_instruction_xilinx_en.doc
3.4
SMART Command
Select '3' to send SMART command to NVMe SSD.
After finishing the operation, SMART/Health Information (output from SMART command) is
be displayed as shown in Figure 3-8. The console shows six parameters, described as
follows.
1) Temperature in °C unit.
2) Total Data Read decoded as GB/TB unit. Additionally, raw data without decoding is
displayed in 128-bit hexadecimal unit. The unit size of raw data is 512,000 Byte.
3) Total Data Written decoded as GB/TB unit. Additionally, raw data without decoding is
displayed in 128-bit hexadecimal unit. The unit size of raw data is 512,000 Byte.
4) Power On Cycles: Display the number of power cycles.
5) Power On Hours: Display the period of time in hours to show how long the SSD has been
powered on.
6) Unsafe Shutdowns: Display the number of unsafe shutdowns of SSD
20-Apr-20
Figure 3-8 Test result when running SMART command
Page 13