CPI Talos T6 Installation Manual - Page 7

Browse online or download pdf Installation Manual for Cash Counters & Coin Sorters CPI Talos T6. CPI Talos T6 18 pages.
Also for CPI Talos T6: Manual (2 pages)

Talos™ T6/T8 Note Validator
On 115 V units, attach the ring terminal of the grounding wire to an earth ground location within the machine. Secure with appropriate
hardware. See Figure 1. To provide strain relief, wrap the enclosed tie-wrap around the closest mounting stud, harness wires, and
ground wire, then pull tie wrap tightly.
On 12 VDC and 24 VAC units, if a metal plate mount is used, connect the ground to the chassis of the host machine. Ensure that the
host machine is properly grounded.
IMPORTANT NOTE TO OEMs: Step 4 must be performed prior to Machine Dielectric Voltage – Withstand Testing Hi-Pot.
Turn on power to the host machine.
Check the LEDs on the front of the note validator. The LEDs should be flashing. In some cases, the machine door must be closed first. If
the LEDs are still not flashing, please refer to
Once the LEDs are flashing, test the validator with a note.
Insert the note into the validator. Confirm that the note stacks and credit is given.
If your machine uses a pulse interface, make sure that the "Pulse Width" and "Pulses Per Dollar" options are configured properly
on the T6/T8 for proper credit. See
Repeat this process for other enabled notes.
When the test is complete, remove the test notes from the note magazine.
The installation is now complete.
01_CPI_Talos T6 and T8 Note Validator_Installation Guide_V2.0_EN
Section 5
of this guide to properly configure the note validator.
Section 5
of this guide.
Published by CPI
7