AR2700 & AR2700M SERIES
Specifications
Introduction
General Safety Instructions
Unit Preparation
Operation / Pump Down Operation
Maintenance
Parts List
Models
Compressor Type
Dimensions
Weight
Operating Range
Power Source
Power Consumption
Suction Pressure Gauge
Discharge Pressure Gauge
Filtration
Manual Control Valves
Charging Valve
Construction
Overload Protection
High Pressure Shut-Off
Refrigerants*
* The AR2700, AR2700A, AR2700E does not contain a pump down valve and is meant for single
refrigerant operation. The AR2700M, AR2700MJ, AR2700ME contains a pump down valve for
mutiple refrigerant usage. Mixing of refrigerants will cause the user economic loss.
Table Of Contents
AR2700 & AR2700M Specifications
AR2700
AR2700M
120 lbs (does not include tank weight)
115 VAC
60Hz 1Ph
16 cubic inch drier w/ moisture indicator, .7 micron oil separator
Ball Type Valves to control HI, LO, Recover, and Vacuum
1" Heavy duty tubular frame construction
10" pneumatic wheels, 4.5" swivel casters
15A Thermal Breaker
R134a, R12, R22, R502, R404a, R402a, R401a, R407c, R409a
AR2700A
AR2700MA
2/3 HP oil less compressor
22" W x 24.5" D x 42" H
0˚C (32˚ F) to 49˚C (120˚)
220-240VAC
50/60Hz 1Ph
850 W
-30 inch Hg to 125 PSIG
0 to 500 PSIG
12 VDC Solenoid Valve
10A Thermal Breaker
30 bar (450 psig)
2
2
3
4
5-7
8-12
13-16
17-18
AR2700E