The following port numbering guidelines apply to all I/O modules except the network daughter card:
● The physical interface name format for the remaining I/O module slots is ethXy, where X is the slot number and y is an
alphanumeric character. For example, eth0a.
● For most horizontal I/O module NIC interfaces, the port numbering goes from left to right, with ethXa on the left.
○ Slots 7 and 8 are reversed, with ethXa on the right.
Slot assignments
The following table lists the slot assignments for the supported I/O modules.
Table 5. I/O Module Slot assignments
Description
Intel XXV710, 2 x 10/25GbE SFP28, PCIe Full Height
Intel X710, 4 x 10GbE SFP+, PCIe Full Height
Intel X710, 4 x 10GBT, PCIe Full Height
QLogic 2692, 2 x 16G FC, PCIe Full Height
Dell EMC Cavium/CN72xx, 16 GB NVRAM, PCIe Full height
Broadcom LSI 9300-8e, 2 x 12 Gbps SAS, PCIe Low Profile
(external SAS)
Intel Lewisberg, QAT, PCIe Full Height
Broadcom LSI 9300-8e, 2 x 12 Gbps SAS, PCIe Low Profile
(internal SAS)
Steps
1. For 10 GBASE-T connections, use one of the following:
● Unshielded Cat 6 cables with RJ-45 connectors that do not exceed 55m
● Cat 6A cables with RJ-45 connectors that do not exceed 100m
2. For 10 GbE-SFP+ optical connections, refer to the list of qualified adapters and use an OM1 160 MHz (2 to 26m), OM1 200
MHz (2 to 33m), OM2 400 MHz, (2 to 66m), OM2 500 MHz (2 to 82m), OM3 1500 MHz (2 to 300m), or OM 4 3500 MHz
(2 to 400m) SFP+ optical cable.
3. For FC connections, use a qualified OM1, OM2, or OM3 Fibre Channel optical cable:
Table 6. Maximum FC cable lengths
Data rate
4 Gbps
8 Gbps
16 Gbps

Connecting disk shelf power cables

Prerequisites
Each disk shelf has two power supplies. Connect each power supply to redundant AC power sources, so the loss of one power
supply or one power source does not cause the shelf to power off.
About this task
ES40 shelves have one power cord per power supply for a total of two power cords.
28
Connect Cables and Power On
OM1 maximum length
70m
21m
15m
Slot
5, 7, 8
5, 7, 8
5, 7, 8
1
2
3
4
6
OM2 maximum length
150m
50m
35m
OM3 maximum length
380m
150m
100m