Figure 9. AC PSU status indicator
1. AC PSU status indicator/handle
Table 16. AC PSU status indicators
Convention
A
B
C
D
E
18
Overview
Power indicator
pattern
Green
Flashing green
Flashing green and turns
off
Flashing amber
Not lit
Condition
A valid power source is connected to the PSU and the PSU is operational.
When the firmware of the PSU is being updated, the PSU handle flashes
green.
When hot-adding a PSU, the PSU handle flashes green five times at 4
Hz rate and turns off. This indicates a PSU mismatch with respect to
efficiency, feature set, health status, and supported voltage.
NOTE:
Ensure that both the PSUs are of the same capacity.
CAUTION:
For AC PSUs, use only PSUs with the Extended Power
Performance (EPP) label on the back.
Indicates a problem with the PSU.
CAUTION:
When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the PSU to make a
matched pair can result in an error condition and unexpected
appliance shutdown. To change from a high output configuration
to a low output configuration or vice versa, you must turn off the
appliance.
CAUTION:
AC PSUs support both 220 V and 110 V input voltages.
When two identical PSUs receive different input voltages, they
can output different wattages, and trigger a mismatch.
CAUTION:
If two PSUs are used, they must be of the same type
and have the same maximum output power.
CAUTION:
Combining AC and DC PSUs is not supported and
triggers a mismatch.
Power is not connected.