Programming the Service Tag

NOTE: The service tag is automatically written to a server module that is replaced in
the field. This procedure is required only if, for some reason, the service tag is not
programmed or is programmed incorrectly.
Connect a null modem cable to the server management module.
1
Open a HyperTerminal session with the following settings:
2
Log into the server management module (ERA/MC) and type the following
3
commands:
racadm setsvctag -m server- x PE1655MC < service_tag >
where x is the slot number of the server module you are updating and
< service_tag > is the valid seven-digit service tag of the server module. For
example, the command for server module number 2 with a service tag of 1234567 is as
follows:
racadm setsvctag -m server-2 PE1655MC 1234567
1-18
Repl aci ng the S er v er Mo dule Bo ard
Set Bits per second to 115200 (default).
Set Data bits to 8.
Set Parity to None.
Set Stop bits to 1.
Set Flow control to HW.