The Digital Display
Indicator and Reminder as Figure 3 shown.
Figure 3. Digital Display
Icon
Description
Salt Level Indicator .
When the salt level is too high, the Indicator will flash green with sound alert, pls
follow the operating alerts in page 8 for the operation action.
When the salt level is too low, the indicator will display green with sound alert, pls
follow the operating alerts in page 8 for the operation action.
Cold Evaporation Filter Replacement Indicator .
Display when the Cold Evaporation Filter should be replaced, based on typical 6
months of operation. See Cold Evaporation Filter Replacing on Page 8.
Water Level Indicator .
When the water level is too low, the indicator will display blue with sound alert, pls
follow the operating alerts in page 8 for the operation action.
HEPA Filter Replacement Indicator .
Display when the 2-in-1 HEPA Filter should be replaced, based on typical 12 months
of operation. See 2-in-1 HEPA Filter Replacing on Page 8.
E1 Indicator
E1
If the Electrolysis Panel is not lowered into position, the unit will beep and an error
code of E1 will be displayed.
7
Operating Alerts
As the Sterilizer operates, the following alerts
may be displayed. Smart AquaSolvo creats a
perfect experience each time!
Salt Level Indicator
Salt Level Indicator
•Flashing blue + sound alarm: High Salt
Alert.
•Operation Action:
1. Power off the device.
2. Empty the Water Tray
3. Wash the CEF
4. Fill with fresh tap water to FULL line + 2
scoops of non-iodized salt to each of
the water containers
•Steady blue + sound alarm: Low Salt Alert.
•Operation action:
1. Power off the device.
2. Fill with fresh tap water to FULL line + 2
scoops of non-iodized salt to each of
the water containers.
Water Level Indicator
•Steady blue + sound alarm: Low Water
Alert.
•Operation action:
1. Power off the device.
2. Fill with fresh tap water to FULL line + 2
scoops of non-iodized salt to each of
the water containers.
E1 Indicator
If the inner Electrolysis Panel is not lowered
into the water tray, the display will show E1 to
remind you.
CEF Replacement Indicator
After 6 months of operation the CEF indicator
will display and an audible alarm will sound.
Refer to CEF replacing actions.
HEPA Filter Replacement Indicator
Will display after 12 months of operation.
Refer to 2-in-1 HEPA Filter replacing actions.

Filter Replacement

2-in-1 HEPA Filter Replacing
It's recommented to replace the 2-in-1 HEPA
filters every 12 months. Or when the 2-in-1
HEPA Filter Indicator is displayed you should
remove and replace the two 2-in-1 HEPA Filters.
1. Using the key, unlock and open the side
panel. The machine will shut down.
2. Remove the two 2-in-1 HEPA filter out of
the left and right side.
NOTE: Handle the old 2-in-1 HEPA filters by
the edges to avoid touching it directly and
preventing possible contamination of the filter
element.
3. Remove 2-in-1 HEPA filters from packaging
and install in the left and right side.
4. Close and lock the side panel.
5. Refer to Preparation for Operation on Page
9 and prepare the salt water solution for
the Sterilizer before resuming operation.
6. Turn on the Sterilizer. After replacing
the filter, press and hold the Filter Reset
Button for 3 seconds to reset the filter life
countdown.
CEF Replacing
The Cold Evaporation Filters should be
replaced every six months, as indicated by the
Cold Evaporation Filters Replacement indicator
on the Control Panel.
1. Using the key, unlock and open the side
panel. The machine will shut down.
2. Remove the two water containers from the
water tray.
CAUTION! Always raise the Electrolysis Panel
up to avoid damaging it when you pull the
Water Tray out.
3. Lift the Electrolysis Panel up so it is clear of
the Water Tray.
8