Dell PowerEdge 4400 User Manual - Page 8

Browse online or download pdf User Manual for Server Dell PowerEdge 4400. Dell PowerEdge 4400 42 pages. Wake-on-lan (wol) support on dell servers
Also for Dell PowerEdge 4400: Installation Manual (42 pages), Installation Manual (20 pages), Installation Manual (28 pages), Rack Installation (37 pages), Update Manual (8 pages), Information Update (8 pages), Rack Installation (34 pages), Hardware Installation Manual (40 pages), Installation Manual (36 pages), Manual (15 pages)

Dell PowerEdge 4400 User Manual
6300 and 4x00
1-4
Dell PowerEdge
Figure 1-2. Back of SCSI Backplane Board
1
Cooling fan power cable connector (FAN)
2
Power connector (POWER)
3
System-board data cable connector (PLANAR)
4
Ultra160/m SCSI cable connector (SCSIA)
14. Connect the power cable labeled "HD-B/P" to the connector labeled "POWER" on
the backplane board.
15. Connect the Ultra160/m SCSI cable leading from the connector labeled "SCSI2"
on the system board to the connector labeled "SCSIA" on the backplane board.
16. Slide the system board tray back into the system chassis.
17 . Does the new SCSI backplane board have a different number of drive bays?
Yes. You must change the orientation of the two drive bay keys to match the new
backplane. Go to step 18.
No. Go to step 25.
18. Remove the front bezel.
19. Turn the key in the keylock to lock the drive locking flange (see Figure 1-3).
With the flange in the locked position, you have easier access to the upper drive
bay key screws.
Systems SCSI Backplane Option