BMC/BIO Version Information
The Get Device command is used to retrieve the intelligent device's hardware revision,
firmware/software revision, and sensor and event interface command specification revision
information. For additional information, refer to the IPMI v2.0 specifications.
Table 1-38.
Get Device Command
Response Data
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Example:
Get device ID:
ipmitool mc info
Response: 0x00 0x25 0x01 0x01 0x00 0x02 0xbf 0xa9 0x19 0x00 0x3b 0x00
0x6e 0x6d 0x00 0x00
This indicates that the BMC version is V1.00.
46
Using the Baseboard Management Controller
Data Field
Completion code
Device ID
Device revision
[7] 1 — Device provides device SDRs
0 — Device does not provide device SDRs
[6:4] — Reserved. Return as 0.
[3:0] — Device Revision, binary encoded
Firmware revision 1
[7] — Device available
0 = Normal operation
1 = Device firmware, SDR repository update or self-initialization in progress.
Firmware/SDR repository updates can be differentiated by issuing a Get SDR
command and checking the completion code.
[6:0] — Major firmware revision, binary encoded
Firmware revision 2: Minor firmware revision. BCD encoded