Dell PowerEdge M610x Getting Started Manual - Page 11

Browse online or download pdf Getting Started Manual for Server Dell PowerEdge M610x. Dell PowerEdge M610x 12 pages. Dell poweredge blade servers getting started guide
Also for Dell PowerEdge M610x: Update Manual (44 pages), Update Manual (21 pages), Update Manual (14 pages), Installation Manual (7 pages), Getting Started Manual (12 pages), Portfolio Manual (27 pages), Technical Manual (48 pages), Getting Started Manual (14 pages), Getting Started Manual (12 pages)

Dell PowerEdge M610x Getting Started Manual
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
Continuous operation: 10 °C to 35 °C at 10% to 80%
relative humidity (RH), with 26 °C max dew point. De-rate
maximum allowable dry bulb temperature at 1 °C/300 m
above 900 m (1 °F per 550 ft).
NOTE: For information on supported expanded
operating temperature range and configurations, see
support.dell.com/manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour
20% to 80% (noncondensing) at a maximum wet bulb
temperature of 29 °C (84.2 °F)
5% to 95% (noncondensing) at a maximum wet bulb
temperature of 38 °C (100.4 °F)
0.26 Grms at 5 Hz to 350 Hz for 15 min
1.54 Grms at 10 Hz to 250 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for up to 2.6 ms
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms
–15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1 ºF/550 ft.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985
11