Also for Dell PowerEdge M610x: Update Manual (44 pages), Update Manual (21 pages), Update Manual (14 pages), Installation Manual (7 pages), Getting Started Manual (12 pages), Getting Started Manual (12 pages), Portfolio Manual (27 pages), Getting Started Manual (14 pages), Getting Started Manual (12 pages)

Dell PowerEdge M610x Technical Manual
Dell

5 Power, Thermal, Acoustic

5.1 Power Supplies

See the
PowerEdge M1000e Technical Guide
specifications.

5.2 Power Efficiency

One of the main features of blade servers is enhanced power efficiency. The M610x achieves higher
power efficiency by implementing the following features:
User-configurable power options through the M1000e Chassis Management Controller (CMC)
(see the M1000e documentation online at
Improved power budgeting
Voltage Regulator (VR) efficiency improvements
CPU VR dynamic phase shedding
Switching regulators instead of linear regulators
Closed loop thermal throttling
Use of DDR3 memory (lower voltage compared to DDR2)
Memory VR static phase shedding
BIOS Power/Performance options page
Active Power Controller (BIOS-based CPU P-state manager)
Ability to throttle memory
Ability to disable a CPU core
Ability to turn off embedded NICs or PCIe lanes when not being used
Energy Smart components at the M1000e chassis level to selectively enable more computing
performance with less power consumption.

5.3 Thermal Operating and Storage Specifications

The M610x thermal solution includes:
Optimized airflow impedance for individual blade and chassis level airflow balancing
Custom air baffling directs airflow through the components to maintain proper cooling
Custom designed heat sinks maintain CPU, DIMM, and board-level chip temperatures within
thermal design targets
Separate airflow cooling path for the two full-length x16 PCIe Gen2 slots.
Support for dual slot NVIDIA
Highly Optimized Fan Control Algorithm
o Base fan speeds are a function of hardware configuration and ambient temperature to
minimize airflow for a given environment.
o Component algorithms: CPU PID, DIMMs, HW Configuration, IOH, GPU, and External
Ambient.
o The highest fan speed request from the above algorithms is used to set the
appropriate fan speed for the blade.
o Ambient and HW Configuration sets the minimum – other algorithms increase fan speed
to maintain proper cooling.
Dell PowerEdge M610x Technical Guide
for information on power supplies and power supply
support.dell.com
®
GPU cards up to 250W.
for further details)
11