Also for Dell PowerEdge R610: Documentation Update (14 pages), Update Manual (32 pages), Information Update (14 pages), Information Update (38 pages), Update Manual (44 pages), Installation Instructions (2 pages), Manual (10 pages), Hardware Installation Instructions (2 pages), Update Manual (14 pages), Portfolio Manual (27 pages), Datasheet (2 pages)

Dell PowerEdge R610 Maintaining And Troubleshooting
Code
Text
E1A15
SAS Cable B
E1A1D
Control panel USB
cable not detected.
E2010
No Memory
E2011
Mem Config Err
E2012
Unusable Memory
E2013
Shadow BIOS Fail
E2014
CMOS Fail
E2015
DMA Controller
E2016
Int Controller
E2017
Timer Fail
E2018
Prog Timer
E2019
Parity Error
E201A
SIO Err
E201B
Kybd Controller
E201C
SMI Init
E201D
Shutdown Test
E201E
POST Mem Test
E2020
CPU Config
November 2010
Causes
SAS cable B is missing or
bad.
USB cable to the control
panel is missing or bad.
No memory is installed in the
system.
Memory detected, but is not
configurable. Error detected
during memory configuration.
Memory is configured, but
not usable. Memory
subsystem failure.
The system BIOS failed to
copy its flash image into
memory.
CMOS failure. CMOS RAM
not functioning properly.
DMA controller failure.
Interrupt controller failure.
Timer refresh failure.
Programmable interval timer
error.
Parity error.
SIO failure.
Keyboard controller failure.
System management
interrupt (SMI) initialization
failure.
BIOS shutdown test failure.
BIOS POST memory test
failure.
CPU configuration failure.
Maintaining and Troubleshooting the Dell
Comments on this document? [email protected]
LCD status message explanations
Corrective action
Escalate for possible server
replacement.
Reseat the cable. If the problem
persists, escalate for possible server
replacement.
Escalate for possible memory or
server replacement.
Escalate for possible server
replacement.
Escalate for possible memory or
server replacement.
Escalate for possible memory or
server replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Escalate for possible server
replacement.
Check for specific error messages.
Table continues...