DH Wireless Solutions PDN Genesis S2 Field Manual - Page 11
Browse online or download pdf Field Manual for Emergency Phone DH Wireless Solutions PDN Genesis S2. DH Wireless Solutions PDN Genesis S2 20 pages.
PDN Genesis
Field Manual
S2
Problem/
Possible
Symptom
Cause
Battery
is not
charged
Gateway
power
is not
connected
Fuse is
blown
Main power
switch is
in "OFF"
position
The DC
source
voltage may
be too low
Fuse is
blown
Verification
Ensure Main power switch is
"ON". Check battery gauge
on front of PDN ensuring
LEDs are displayed. Full
battery charge is indicated
by the top LED on battery
gauge. If LEDs are not lit,
charge on batteries may
have fallen too low.
Check LED in service
cover window. The power
LED should be on when
power is above 9 volts. If
LEDs are off, gateway is not
getting power.
Remove service cover. Open
black rubber cover on fuse
holder connected to battery
charger. Remove fuse and
verify center strip is intact.
DC power is disconnected
when the main power switch
is off. Battery gauge LEDs
will not display.
Use a voltmeter to check
source voltage. Ensure
voltage source has a
minimum of 9 volts DC
and 1.5 AMPs.
Remove service cover.
Open black rubber cover on
fuse holder of wire harness.
Remove fuse and check if
center strip is intact.
11
Possible
Corrections
Use AC power to charge
battery and power gateway
while battery is charging.
If AC power is not available,
then use DC power input
with DC cable in accessories
pouch.
NOTE: When using DC
power only, batteries will not
charge.
Remove service cover to
ensure gateway power
cable is connected firmly
into back of gateway
connected into wire
harness connector.
Replace the fuse with
a mini blade fuse of
same amperage
rating printed
on top of fuse.
Open case and ensure
Main Power Switch in
upper left corner of service
cover is in "ON" position.
Change the external DC
source or switch to a power
source with adequate
charge and voltage.
Replace fuse with mini
blade fuse of same
amperage rating printed
on top of fuse.
877.524.0430