Dell VEP4600 Installation Manual - Page 33

Browse online or download pdf Installation Manual for Server Dell VEP4600. Dell VEP4600 40 pages.
Also for Dell VEP4600: Setup Manual (23 pages), Installation Manual (40 pages)

Dell VEP4600 Installation Manual
This section lists the VEP4600 specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 113°F (45°C).
NOTE:
For RoHS information, see
Topics:

Chassis physical design

IEEE standards
Safety standards and compliance agency certifications
Product recycling and disposal
Agency compliance
Chassis physical design
Table 6. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 7. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Restricted Material Compliance
Specifications
1.72 inches (43.6 mm)
17.1 inches (434 mm)
● 15 inches (381 mm)
● PSU/fan tray handle: 1.57 inches (40 mm)
16.40lbs (7.43 kg), (2 PSUs, and 5 fans, 1 rNDC card)
● Front: 5 inches (12.7 cm)
● Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (32°F to 113°F) continuously
● 5% to 85% (RH), non-condensing, continuously
● 5% to 90% (RH), non-condensing, short term
● Short term is </= 1% of operational hours per year.
–40°F to 70°C (–40°F to 158°F)
5% to 95%, non-condensing
311 W = 1024 BTU/Hr
10,000 feet (3,048 meters)
35,000 feet (10,688 meters)
SV0115 — ODM
Specifications
.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
8
Specifications
33