Dell VEP4600 Installation Manual - Page 33
Browse online or download pdf Installation Manual for Server Dell VEP4600. Dell VEP4600 40 pages.
Also for Dell VEP4600: Setup Manual (23 pages), Installation Manual (40 pages)
This section lists the VEP4600 specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 113°F (45°C).
NOTE:
For RoHS information, see
Topics:
•
Chassis physical design
•
IEEE standards
•
Safety standards and compliance agency certifications
•
Product recycling and disposal
•
Agency compliance
Chassis physical design
Table 6. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 7. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Restricted Material Compliance
Specifications
1.72 inches (43.6 mm)
17.1 inches (434 mm)
● 15 inches (381 mm)
● PSU/fan tray handle: 1.57 inches (40 mm)
16.40lbs (7.43 kg), (2 PSUs, and 5 fans, 1 rNDC card)
● Front: 5 inches (12.7 cm)
● Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (32°F to 113°F) continuously
● 5% to 85% (RH), non-condensing, continuously
● 5% to 90% (RH), non-condensing, short term
● Short term is </= 1% of operational hours per year.
–40°F to 70°C (–40°F to 158°F)
5% to 95%, non-condensing
311 W = 1024 BTU/Hr
10,000 feet (3,048 meters)
35,000 feet (10,688 meters)
SV0115 — ODM
Specifications
.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
8
Specifications
33