Dell Vostro 220 - Vostro 220 Slim Desktop Computer Service Manual - Page 41
Browse online or download pdf Service Manual for Server Dell Vostro 220 - Vostro 220 Slim Desktop Computer. Dell Vostro 220 - Vostro 220 Slim Desktop Computer 44 pages. Rack installation guide
Also for Dell Vostro 220 - Vostro 220 Slim Desktop Computer: Specifications (1 pages), Setup And Features Information (10 pages), Rack Installation Manual (40 pages)
1. Insert the new microprocessor into the system board connector.
Press the processor firmly into its connector until it is fully seated. You must use up to 25 lb of force to fully seat the processor in its connector.
2. Replace the airflow shroud.
Squeeze in on the two pairs of tabs on the shroud, align it with the slots in the microprocessor fan, and lower it into place.
3. After you
replace the computer cover
correctly.
Microprocessor Cooling Fan
Figure 31. Microprocessor Cooling Fan Removal
To remove the microprocessor cooling fan, perform the following steps:
1.
Remove the computer
cover.
2.
Rotate the system power
and
restart the
system, run the Dell Diagnostics to verify that the new microprocessor is operating
1 Fan power cable
2 Fan
3 Plastic lock
4 Latching tabs (4)
supply.
1 Airflow shroud
2 Thumbscrews (2)
3 Processor/heat sink assembly
4 Guide bracket
5 Second processor (terminator card if a second
processor is not present)