EarthCore ISOKERN Standard 46 Installation, Operating, Maintenance And Owner's Manual - Page 8
Browse online or download pdf Installation, Operating, Maintenance And Owner's Manual for Outdoor Fireplace EarthCore ISOKERN Standard 46. EarthCore ISOKERN Standard 46 12 pages. Isokern outdoor fireplace
The firebox side walls must sit three inches (3")
on the base plate. Since the side wall components flair from
three inches (3") at the narrow end to eight inches (8") on
the wide end, the side walls will overhang the base plate by
approximately five inches (5") at their wide end. Support this
overhang with masonry.
See-Thru or two-sided fireplaces can be constructed
from the one-sided unit components by eliminating the back
wall assembly.
In this installation the firebox side wall components
are reversed so that the side wall taper sits to the outside of the
box leaving the inside of the see-thru firebox with two straight
and parallel interior walls.
Angle steel three inch by three inch by one quarter
inch (3" x 3" x 1/4") should be set on top of the side wall
assembly to span each of the openings of the see-thru before
the top plate is set into place.
The steel can be set with the angle leg either up or
down.
Specialty Applications: See-Thru
Model
A
36"
43"
42"
49"
46"
53"
B
C
36 1/8"
53"
43 1/8"
59"
47 1/8"
63"
8
B
A
C