Dell EqualLogic PS5500 Hardware Manual - Page 22

Browse online or download pdf Hardware Manual for Storage Dell EqualLogic PS5500. Dell EqualLogic PS5500 50 pages. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters
Also for Dell EqualLogic PS5500: Maintenance Manual (8 pages)

Dell EqualLogic PS5500 Hardware Manual
Cabling The Dell EqualLogic PS6000/PS6100/PS6500 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3.
Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 3 on the control module 1.
5.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
6.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
7.
Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
8.
Connect a network cable from the network switch 0 to Ethernet 3 on the control module 0.
9.
Repeat steps 1 to 8 to connect the additional Dell EqualLogic PS6000/PS6100/PS6500 storage array(s) to the iSCSI
switches.
NOTE: For PS6100 storage array, having all eight cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only four cables. You can skip either step 1 or 5, either step 2 or 6, either step 3 or 7,
and either step 4 or 8.
For more information, see the figures below.
Figure 15. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS6000 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
22
5. Dell EqualLogic PS6000 storage system
6. control module 1
7. control module 0