Dell Express Flash NVMe PCIe SSD AIC User Manual - Page 10

Browse online or download pdf User Manual for Storage Dell Express Flash NVMe PCIe SSD AIC. Dell Express Flash NVMe PCIe SSD AIC 15 pages.

State Name
Read only
Predicted failure

Ungraceful system shutdown or power loss

If the host system experiences a power loss, the NVMe PCIe SSD may not have time to perform its internal shut down procedure. In such
an event, the device may enter a recovery mode.
This recovery process is also known as rebuilding. During rebuilding, there is very limited access from the host operating system. After the
recovery procedure is complete, the device is fully accessible from the host operating system.
NOTE:
Dell recommends that you use power backup solutions for all Dell systems.

General errors

The following section describes general errors related to NVMe PCIe SSD.

NVMe drive properties intermittently not available in iDRAC

Description
NVMe drive properties via sideband (iDRAC) may not be available after a PCIe SSD is hot-inserted into the system.
This is most likely to occur if the PCIe SSD is formatted with a file system or has existing data.
Cause
Side band controller on the NVMe drives does not complete initialization in time for iDRAC to inventory the device.
Solution
After an AC power cycle, the system should list the inserted devices in iDRAC.

NVMe PCIe SSD is not listed in the operating system

Cause
Hardware is not correctly installed.
Solution
Check the following components:
10
Troubleshooting
Slot/Device State
responding or has encountered a
critical error condition.
The device will only service read
operations.
The SMART feature set has
predicted a degradation or fault
condition.
Devices: Ensure that the NVMe PCIe SSDs are installed in an NVMe PCIe SSD backplane.
NOTE:
NVMe PCIe SSDs must be used with NVMe PCIe SSD backplanes. To ensure that you
have the correct configuration for the NVMe PCIe SSD, see the platform-specific Owner's
Manual at Dell.com/support/manuals.
Backplane: Ensure that the cables for the NVMe PCIe SSD backplane are connected correctly.
Cables: PCIe cables are unique for the configuration. Ensure that the backplane cable connectors are
connected to the backplane and the extender card or system board.
Extender card: Ensure that the PCIe extender card, if used in your server configuration, is plugged into the
correct supported slot. See the system specific owner's manual at Dell.com/support/manuals.
Status LED (Green)
Off
Off for 250 msec
On for 250 msec
Status LED (Amber)
On for 250 msec
Off for 250 msec
On for 250 msec
Off for 250 msec