Dell PowerEdge 4400 Installation Manual - Page 9

Browse online or download pdf Installation Manual for Storage Dell PowerEdge 4400. Dell PowerEdge 4400 36 pages. Wake-on-lan (wol) support on dell servers
Also for Dell PowerEdge 4400: Installation Manual (42 pages), Installation Manual (20 pages), Installation Manual (28 pages), Rack Installation (37 pages), Update Manual (8 pages), Information Update (8 pages), User Manual (42 pages), Rack Installation (34 pages), Hardware Installation Manual (40 pages), Manual (15 pages)

Dell PowerEdge 4400 Installation Manual
support.dell.com
7 .
Remove any front-panel inserts on the front bezel that block the external
drive bay.
See "Installing Drives in the External Bays," in the Installation and
Troubleshooting Guide for detailed information on removing the front-panel
inserts.
8.
Replace the front bezel and computer cover.
9.
Reconnect the computer and peripherals to their electrical outlets, and turn
them on.
10. Install any required SCSI device drivers.
See "Installing and Configuring SCSI Drivers," in your system's User's Guide for
information.
11. If the hard-disk drive is a new drive, run the SCSI Devices test group in the Dell
Diagnostics.
See "Running the Dell Diagnostics," in the Installation and Troubleshooting
Guide for information.
Removing the External Drive Bay
To remove the external drive bay, use the following procedure:
1.
Shut down the system, turn off the computer and any attached peripherals, and
disconnect the computer and peripherals from their electrical outlets.
2.
Remove the computer cover and front bezel.
See the Installation and Troubleshooting Guide for instructions on removing the
computer cover and front bezel.
3.
Remove the SCSI, system management cable connector (marked FDHDBP), and
DC power cables from the back of the hard-disk drive.
4.
Press inward on the two release tabs on the drive bay assembly, and pull the
assembly about one inch out of the external drive bay.
5.
Remove the flush-mount screw that secures the locking bar on the front of the
assembly and remove the locking bar.
6.
Open the drive carrier handle and slide the carrier out of the drive bay.
7 .
Insert the drive-bay filler panel or a replacement hard-disk drive and its carrier in
the empty drive slot.
8.
Replace the locking bar and the screw you removed in step 5.
9.
Slide the drive bay assembly back into the external drive bay.
NOTE: If you installed a drive bay filler panel, go to step 11.
Dell PowerEdge Systems — Installing the External Drive Bay
1-5