Dell PowerEdge Express Flash NVMe PCIe SSD User Manual - Page 29
Browse online or download pdf User Manual for Storage Dell PowerEdge Express Flash NVMe PCIe SSD. Dell PowerEdge Express Flash NVMe PCIe SSD 32 pages.
NVMe PCIe SSD Performance Measurement Not Optimal
Description
There are a number of factors that may alter the performance of an NVMe PCIe
SSD. It is recommended to take basic setup measures to ensure performance
optimization of these devices.
Cause
NVMe PCIe SSD has not been pre-conditioned and/or BIOS settings are not
optimal.
Solution
•
•
In Windows Server 2012 R2, OpenManage Server Administrator Does Not
Detect PCIe NVMe Devices
Description
Windows Server 2012 R2 contains an in-box NVMe driver, which is not supported
by Dell OpenManage Server Administrator.
Cause
The operating system is using the in-box NVMe driver.
Solution
Install the latest NVMe driver available on dell.com/support.
Windows Event ID 11 Error Reported In Windows Event Log
Description
Event ID 11 Error is reported in the Windows event log during each system boot.
Cause
This issue exists in the in-box Windows NVMe driver.
Solution
Install the latest NVMe driver available on dell.com/support.
Without pre-conditioning the NVMe PCIe SSD, performance measurements can
be misleading as they may not reflect long term performance of the device.
Pre-conditioning activates flash management, which stabilizes data throughput
over a period of time. For the Solid State Storage Performance Test
Specification, refer to snia.org.
Configure the server for low latency performance. To achieve maximum
performance with Dell PowerEdge Express Flash NVMe PCIe SSDs, change the
server performance profile in the BIOS settings to Performance.
29