Dell PowerVault 220S Manual - Page 35

Browse online or download pdf Manual for Storage Dell PowerVault 220S. Dell PowerVault 220S 44 pages. Dell powervault 220s and 221s systems scsi drive enclosure
Also for Dell PowerVault 220S: Notice (28 pages), Updating Firmware (14 pages), Service Manual (33 pages)

Dell PowerVault 220S Manual
A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS
Level
RAID 0
RAID 1
RAID 5
RAID 10
RAID 50
Capacity Needs – Virtual Disk Size

Additional RAID information

http://support.dell.com/support/edocs/storage/RAID/RAIDbk0.pdf
PAGE 35
• Table 5-1: Pros and Cons for Spanning Arrays with various RAID Levels
Pros
Improves data throughput by
optimizing bandwidth utilization
Improves data availability
against channel failures, if
mirrored set is spanned across
separate channel
May improve data throughput for
certain accesses, if data and
parity for the access span
across channels
Improves data availability
against channel failures, if
mirrored set is spanned across
separate channel
May improve data throughput,
similar to spanned RAID5
Note: Dell PERC controllers don't support spanning of arrays across different
controllers. Spanning across channels on the same PERC controller is only
supported.
Virtual disks on SCSI PERC controllers cannot be created with an aggregate
size greater than 2TB due to limitations on SCSI controllers and operating
systems. Host management application (OMSM, Array Manager) will give an
error if an attempt is made to make virtual disk greater than 2TB, prompting
user to reduce size of virtual disk. For more information please refer to
"Beyond The 2-TB SCSI Logical Unit" white paper at:
http://www.dell.com/downloads/global/vectors/2004_2tblun.pdf.
Dell 'Getting Started with RAID' document
o
Cons
Reduces reliability and availability of data
with additional point of failure – second
channel
If PV22xS is used on both channels
(either in Split of Joined topology), limits
the usage of PERC on internal channel
(connecting devices to the same channel
on internal and external connectors is
not supported)
Even though RAID5 provides data
protection but compromises reliability
and availability of data at SCSI channel
level
If PV22xS is used on both channels
(either in Split of Joined topology), limits
the usage of PERC on internal channel
(connecting devices to the same channel
on internal and external connectors is
not supported)
Reduces reliability and availability of data
as compared to non-spanned RAID50 at
SCSI channel level
VER A02
11/17/2005