Also for Dell PowerVault MD3200 Series: Update Manual (32 pages), Rack Installation Instructions (2 pages), Support Matrix (12 pages), Installation Manual (18 pages), Deployment Manual (38 pages), Information Update (1 pages), Support Matrix (17 pages), White Paper (22 pages), Deployment Manual (38 pages), Deployment Manual (38 pages)

Dell PowerVault MD3200 Series Technical Manualbook
Technical Guide Book for PowerVault MD3200MD3220
Table 10.
Environmental Specifications
Temperature
Operating
Storage
Relative Humidity
Operating
Storage
Maximum Vibration
Operating
Storage
Maximum Shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
10° to 35°C (50° to 95°F) with a maximum temperature gradation
of 10°C per hour
Note: For altitudes above 2950 feet, the maximum operating
temperature is de-rated 1°F/550 ft.
-40° to 65°C (-40° to 149°F) with a maximum temperature
gradation of 20°C per hour
20% to 80% (non-condensing) with a maximum humidity
gradation of 10% per hour
5% to 95% (non-condensing) with a maximum humidity gradation
of 10% per hour
0.25 G at 3 – 200 Hz for 15 min
0.5 at 3 – 200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each side of
the system) of 31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 71 G for up to 2 ms
-16 to 3048 m (-50 to 10,000 ft)
Note: For altitudes above 2950 feet, the maximum operating
temperature is de-rated 1°F/550 ft.
-16 to 10,600 m (-50 to 35,000 ft)
G2 or lower as defined by ISA-S71.04-1985
37