Dell PowerVault MD3260 Series Getting Started Manual - Page 8

Browse online or download pdf Getting Started Manual for Storage Dell PowerVault MD3260 Series. Dell PowerVault MD3260 Series 9 pages. Dell powervault md3260/3260i/3660i/3660f/3060e storage arrays
Also for Dell PowerVault MD3260 Series: Hardware And Software Manual (25 pages), Installation Manual (11 pages), Getting Started Manual (10 pages), Information Update (8 pages), Rack Installation Instructions (2 pages), Setting Up (2 pages), Deployment Manual (26 pages), Configuration Manual (17 pages), Deployment Manual (24 pages)

Dell PowerVault MD3260 Series Getting Started Manual
Power
NOTE: This system is also designed to be
connected to IT power systems with a phase
to phase voltage not exceeding 230 V.
Battery
Physical
Height
Width
Depth
Weight (maximum configuration)
Weight (empty)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating and
Storage)
Storage Temperature Limits
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950
m or 3117 ft)
Humidity Percentage Range
Relative humidity
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
8
6.6 V DC, 1100 mAh, 7.26 W Lithium Ion Battery
177.80 mm (7.0 inch)
482.60 mm (19.0 inch) with rack latches
825.50 mm (32.5 inch) without bezel and handle
105.20 kg (232.0 lb)
19.50 kg (43.0 lb)
20 °C/hour (36 °F/hour)
-40 °C to 65 °C (-40 °F to 149 °F)
10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the
equipment
NOTE: For information on supported expanded operating
temperature range and configurations, see the
Manual dell.com/support/manuals.
10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew
point.
5% to 95% RH with 33 °C (91 °F) maximum dew point.
Atmosphere must be non-condensing at all times
0.26 G
at 5 Hz to 350 Hz in operational orientation
rms
1.88 G
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
rms
One shock pulse in the positive z axis (one pulse on each side
of the system) of 31 G for 2.6 m in the operational orientation.
Owner's