Also for Dell PowerVault MD3260i Series: Hardware And Software Manual (25 pages), Installation Manual (11 pages), Getting Started Manual (10 pages), Information Update (8 pages), Rack Installation Instructions (2 pages), Setting Up (2 pages), Troubleshooting Manual (18 pages), Deployment Manual (24 pages)

Dell PowerVault MD3260i Series Troubleshooting Manual
Using VLAN tagging
packet transmission.
On Windows-based hosts, send a 9000-byte
packet to 192.168.130.101 using the following
command:
ping –l 9000 192.168.130.101
On Linux-based hosts, use this command to
perform the same function:
ping –s 9000 192.168.130.101
If the ping is successful, the packet
transmission has completed. If ping does not
work, the packet was dropped.
NOTE: Make sure that all components along the data path
support the MTU size you are specifying.
Verify that the VLAN ID of the iSCSI host ports are set
to the same values you are using for VLAN tagging. All
tag values must be the same for the host server,
switch and server array.