Dell PowerVault MD3660i Series Storage Array Troubleshooting Manual - Page 20

Browse online or download pdf Troubleshooting Manual for Storage Dell PowerVault MD3660i Series Storage Array. Dell PowerVault MD3660i Series Storage Array 20 pages. Storage arrays
Also for Dell PowerVault MD3660i Series Storage Array: Hardware And Software Manual (25 pages), Installation Manual (11 pages), Getting Started Manual (10 pages), Information Update (8 pages), Rack Installation Instructions (2 pages), Setting Up (2 pages), Troubleshooting Manual (18 pages), Deployment Manual (24 pages)

Dell PowerVault MD3660i Series Storage Array Troubleshooting Manual
ESX-based host servers will not fail back
LUNs automatically when a VNOP error is
encountered
Map each VMkernel port to only one
active adapter
switches with different subnet address, as well as
physically separate network switches. Setting up
management and iSCSI traffic on the same
networks may result in network congestion and
performance loss.
You must redistribute the virtual disks in MD
Storage Manager
By default, each VMkernel port on the vSwitch
shows all network adapters as active. You must
manually override this setting so that each port
maps to only one corresponding active adapter.
(For example, VMkernel port vmk1 should map to
active adapter vmnic1, VMkernel port vmk2 should
map to vmnic2, etc.)
To perform this manual override:
1. Log in to the vSphere Client and select the host
server.
2. From the Ports tab, select a VMkernel port and
click Edit.
3. Click the NIC Teaming tab and select Override
vSwitch failover order.
4. Designate only one adapter as active and move all
remaining adapters to the Unused Adapters
category.
5. Repeat steps 1 through 4 for each VMkernal port.
20