Dell PowerVault NX1950 Getting Started - Page 12

Browse online or download pdf Getting Started for Storage Dell PowerVault NX1950. Dell PowerVault NX1950 49 pages. For vmware esx server software
Also for Dell PowerVault NX1950: Deployment Manual (34 pages), Important Information Manual (26 pages), Installation And Troubleshooting Manual (48 pages), Deployment Manual (38 pages), Upgrade Manual (18 pages), Reference Manual (4 pages), Setting Up (2 pages), Using (2 pages), Configuration Manual (11 pages)

Dell PowerVault NX1950 Getting Started
Physical
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
10
Getting Started With Your System
4.29 cm (1.69 in)
48.26 cm (19 in)
76.2 cm (30 in)
17.69 kg (39 lb)
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
8% to 85% (noncondensing) with a maximum humidity gradation
of 10% per hour
5% to 95% (noncondensing)
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each side
of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the positive and negative
x, y, and z axes (one pulse on each side of the system) of 71 G
for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)