Dell SC180 Owner's Manual - Page 30

Browse online or download pdf Owner's Manual for Storage Dell SC180. Dell SC180 39 pages. Storage center
Also for Dell SC180: Owner's Manual (37 pages)

Dell SC180 Owner's Manual

Replacing an Enclosure Management Module

The SC180 expansion enclosures support redundant hot-swappable Enclosure Management Modules
(EMMs).
EMMs provide the following data path and enclosure management functions for the expansion
enclosure:
Monitoring and controlling expansion enclosure environment elements such as temperature, fan,
power supplies, and expansion enclosure LEDs
Controlling access to hard drives
Communicating expansion enclosure attributes and states to Storage Center

Identifying the Failed Enclosure Management Module

To determine which enclosure management module (EMM) failed, use the Dell Storage Client.
1.
Start the Dell Storage Client and connect to the Storage Center that has an expansion enclosure with
a failed EMM.
2.
Click the Hardware tab.
3.
In the Hardware tab navigation pane, select and expand the Storage Center.
4.
In the Hardware Alerts area, find the hardware alert that identifies the expansion enclosure with the
failed EMM.
Figure 22. Hardware Alert Identifying the Expansion Enclosure with the Failed EMM
5.
In the Hardware tab navigation pane, expand the expansion enclosure identified in the previous step.
6.
Select I/O Modules. The status of each EMM is displayed in the I/O Modules tab.
7.
Select the failed EMM. The location of the failed EMM is displayed in the I/O Module View tab.
30
Replacing SC180 Expansion Enclosure Components