Dell SCv2080 Owner's Manual - Page 44

Browse online or download pdf Owner's Manual for Storage Dell SCv2080. Dell SCv2080 49 pages. Storage center
Also for Dell SCv2080: Getting Started Manual (24 pages), Getting Started Manual (23 pages), Owner's Manual (45 pages)

Dell SCv2080 Owner's Manual

Troubleshooting SCv2080 Components

This section contains basic troubleshooting steps for components inside the SCv2080 storage systems.

Troubleshooting PSUs

To troubleshoot power supply units (PSUs):
1.
Check the status of the PSU using the Dell Storage Client.
2.
Determine the status of the PSU LEDs.
If the PSU fault indicator is lit, the PSU has failed.
If the Power OK LED is not lit, check the power cord and power source into which the power
supply is plugged:
– Connect another device to the power source and check whether the device works.
– Connect the power cord to a different power source.
– Replace the power cord.
If the AC fault LED is lit, this PSU is not supplying power, though the other PSU may still be
supplying power.
3.
Reseat the PSU by removing and reinstalling it.
NOTE: Allow several seconds for the storage system to recognize the PSU and determine its
status.

Troubleshooting Cooling Fan Modules

To troubleshoot cooling fan modules:
1.
Check the status of the cooling fan module using the Dell Storage Client.
2.
Determine the status of the cooling fan module LEDs.
If the cooling fan fault indicator is lit, the cooling fan module has failed.
3.
Reseat the cooling fan module by removing and reinstalling it.
NOTE: Allow several seconds for the storage system to recognize the cooling fan module and
determine its status.

Troubleshooting Hard Drives

To troubleshoot hard drives:
1.
Check the status of the hard drive using the Dell Storage Client.
2.
Determine the status of the DDIC LED.
If the DDIC fault LED is lit, the hard drive has failed.
44
Troubleshooting SCv2080 Components