Dell SCv2080 Owner's Manual - Page 10

Browse online or download pdf Owner's Manual for Storage Dell SCv2080. Dell SCv2080 45 pages. Storage center
Also for Dell SCv2080: Owner's Manual (49 pages), Getting Started Manual (24 pages), Getting Started Manual (23 pages)

Dell SCv2080 Owner's Manual
SCv2080 Storage System Back-Panel Features and
Indicators
The back panel shows power, connectivity, and fault indicators.
Figure 2. SCv2080 Back-Panel Features and Indicators
Item
Name
1
Optional cable
retention positions
(4)
2
Storage controller
(2)
3
Cooling fans (5)
4
Power supply units
(2)
10
Icon
Description
Locations for optional cable retention brackets.
Each storage controller module contains:
Battery backup unit (BBU): Allows the storage controller
to shut down gracefully when a loss of AC power is
detected.
Back-end ports: Two 6 Gbps SAS ports
Front-end ports: Fibre Channel ports, iSCSI ports, or SAS
ports
MGMT port: Embedded Ethernet/iSCSI port, which is used
for system management
NOTE: The MGMT port can share iSCSI traffic if the
Flex Port license is installed.
REPL port: Embedded iSCSI port, which is typically used
for replication to another Storage Center
NOTE: A Flex Port license is required to connect host
servers through the embedded iSCSI ports.
Fans that provide cooling for the storage system.
2.8 kW power supply that provides power for the storage
system.
Get other manuals https://www.bkmanuals.com
About the SCv2080 Storage System