Dell Brocade VDX 6940 Configuration Manual - Page 11

Browse online or download pdf Configuration Manual for Switch Dell Brocade VDX 6940. Dell Brocade VDX 6940 12 pages. Ps series

Dell Brocade VDX 6940 Configuration Manual
4

Configuring VCS ID and Rbridge ID

Refer to Brocade documentation for details on VCS and Ethernet fabric. The following steps configure the
Rbridge ID and VCS ID to 2 on the second switch so that it does not conflict with the default value of 1 on
switch 1. VDX 6740 is in Fabric Cluster Mode by default and configuration change is not required for the
mode.
sw0# show vcs
Config Mode
VCS Mode
VCS ID
Total Number of Nodes
Rbridge-Id
Fabric Status
--------------------------------------------------------------------------------
------------------------------
2
Online
sw0# vcs vcsid 2
This operation will change the configuration to default and reboot the switch.
Do you want to continue? [y/n]:y
Note: The switch will reboot.
sw0# vcs rbridge-id 2
This operation will change the configuration to default and reboot the switch.
Do you want to continue? [y/n]:y
Note: The switch will reboot.
11
Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306
: Local-Only
: Fabric Cluster
: 1
: 1
WWN
HostName
>10:00:50:EB:1A:2D:F2:64*
sw0
Management IP
VCS Status
77.77.77.77
Online