Dell Force10 S4810 Configuration Manual - Page 8

Browse online or download pdf Configuration Manual for Switch Dell Force10 S4810. Dell Force10 S4810 17 pages. Dell force10 s4810 switch
Also for Dell Force10 S4810: Quick Start Manual (27 pages), Deployment Manual (36 pages), Configuration Manual (17 pages)

Dell Force10 S4810 Configuration Manual
2.4

Configure route for OOB management port (optional)

FTOS(conf)#management route X.Y.Z.0 /24 A.B.C.1
Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
2.5

Configure login credentials

FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
2.6

Enable switch ports

Option 1: You can enable ports individually by entering the port number.
FTOS#configure
FTOS(conf)#interface tengigabitethernet 0/0
FTOS(conf-if-te-0/0)#switchport
FTOS(conf-if-te-0/0)#no shutdown
FTOS(conf-if-te-0/0)#exit
FTOS(conf)#exit
Option 2: You can enable multiple ports at once using the 'range' parameter.
FTOS#configure
FTOS(conf)#interface range tengigabitethernet 0/0 – 47
FTOS(conf -if-range-te-0/0-47)#switchport
FTOS(conf -if-range-te-0/0-47)#no shutdown
FTOS(conf -if-range-te-0/0-47)#exit
FTOS(conf)#exit
2.7

Enable Jumbo Frames

FTOS#configure
FTOS(conf)# interface range tengigabitethernet 0/0 – 47
FTOS(conf -if-range-te-0/0-47)#mtu 12000
2.8

Configure flow control

FTOS(conf -if-range-te-0/0-47)#flowcontrol rx on tx off
8
SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs