Dell PowerEdge M420 Getting Started Manual - Page 9

Browse online or download pdf Getting Started Manual for Switch Dell PowerEdge M420. Dell PowerEdge M420 14 pages. Dell poweredge blade servers getting started guide
Also for Dell PowerEdge M420: Information Update (38 pages), Release Notes (27 pages), Manual (25 pages), User Manual (23 pages), Important Information Manual (35 pages), Update Manual (32 pages), Update Manual (28 pages), User Manual (26 pages), User Manual (22 pages), Getting Started Manual (12 pages), Manual (38 pages), Technical Manual (46 pages), Technical Manual (48 pages), Portfolio Manual (27 pages), Getting Started Manual (12 pages)

Dell PowerEdge M420 Getting Started Manual
Model number:
Supply voltage:
Frequency:
Current consumption:
Model number:
Supply voltage:
Current consumption:
Model number:
Supply voltage:
Current consumption:
Model number:
Supply voltage:
Current consumption:

Technical Specifications

NOTE: For additional specifications, see your system
Power — Blades
Coin-cell battery
Power — Enclosure
AC/DC power supply (per power supply module) (2700 W)
Wattage
Connector
Heat dissipation
Maximum inrush current
AC/DC power supply (per power supply module) (3000 W)
Wattage
Connector
Col. Lomas Altas
11950 México, D.F.
BMX01
100 V CA to 240 V CA (with 2700 W AC power supply units) or –(48–60) V CC (with
2700 W DC power supply units)
200 V CA to 240 V CA (with 3000 W AC power supply units)
50 Hz/60 Hz or N/A
16 A (x6) or 75 A (x6)
FHB
12 V CC
75 A
HHB
12 V CC
37 A
QHB
12 V CC
35 A
Owner's Manual .
3 V CR2032 Lithium coin cell
2700 W
IEC C20
1205 BTU/hr (maximum)
Under typical line conditions and over the entire system
ambient operating range, the inrush current may reach
55 A per power supply for 10 ms or less.
3000 W
IEC 320
9