Also for Dell PowerEdge M620: Information Update (38 pages), Release Notes (27 pages), Manual (25 pages), User Manual (23 pages), Important Information Manual (35 pages), Update Manual (32 pages), Update Manual (28 pages), User Manual (26 pages), User Manual (22 pages), Getting Started Manual (12 pages), Getting Started Manual (12 pages), Technical Manual (46 pages), Technical Manual (49 pages), Portfolio Manual (27 pages), Technical Manual (44 pages), Getting Started Manual (14 pages)

Dell PowerEdge M620 Getting Started Manual
Physical — Blades
Weight (maximum)
Physical — Enclosure
Height
Width
Depth
Weight (maximum)
Weight (empty)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
2.3 kg (5.07 lb)
44.0 cm (17.3 inch)
44.7 cm (17.6 inch)
75.5 cm (29.7 inch)
200.5 kg (442 lb)
44.6 kg (98.1 lb)
Continuous operation: 10 °C to 35 °C at 10% to 80%
relative humidity (RH), with 26 °C max dew point. De-rate
maximum allowable dry bulb temperature at 1 °C per 300
m (1 °F per 550 ft) above 900 m (2952.75 ft).
NOTE: For information on supported expanded
operating temperature range and configurations,
see support.dell.com/manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour
10% to 80% relative humidity (RH), with 26 °C max dew
point
5% to 95% (noncondensing) at a maximum wet bulb
temperature of 38 °C (100.4 °F)
0.26 G
at 5 Hz to 350 Hz for 15 min
rms
1.54 G
at 10 Hz to 250 Hz for 15 min
rms
One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for up to 2.6 ms
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms
–15.2 m to 3048 m (–50 ft to 10,000 ft)