Dell PowerEdge M820 Systems User Manual - Page 23

Browse online or download pdf User Manual for Switch Dell PowerEdge M820 Systems. Dell PowerEdge M820 Systems 23 pages. Dell poweredge blade servers getting started guide
Also for Dell PowerEdge M820 Systems: Information Update (38 pages), Release Notes (27 pages), Important Information Manual (35 pages), Update Manual (32 pages), Update Manual (28 pages), User Manual (26 pages), User Manual (22 pages), Getting Started Manual (12 pages), Owner's Manual (3 pages), Technical Manual (46 pages), Portfolio Manual (27 pages), Getting Started Manual (14 pages), Getting Started Manual (12 pages), Technical Manual (47 pages)

Dell PowerEdge M820 Systems User Manual
Rev 1.0
Table 9 - SFP+ Pinout
Pin
Symbol Name
15
VccR
16
VccT
17
VeeT
18
TD+
19
TD-
20
VeeT
a. Circuit ground is internally isolated from chassis ground.
b. T
FAULT
Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V
to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias cur-
rent or the TX output power exceeding the preset alarm thresholds. A low output indicates
normal operation. In the low state, the output is pulled to <0.8V.
c. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V
d. Should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V.
MOD_ABS pulls line low to indicate module is plugged in.
e. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩ on host board to a
voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of
signal.
24
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground (Common with Receiver Ground)
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)
is an open collector/drain output, which should be pulled up with a 4.7k – 10k
Description
a
a