Dell S50-01-SSC-24G Specifications - Page 2
Browse online or download pdf Specifications for Switch Dell S50-01-SSC-24G. Dell S50-01-SSC-24G 2 pages. S25v and s50v s-series power-over-ethernet switches
Specifications: S-Series Power-over-Ethernet Switches
Ordering Information
Order Number
Description
S25-01-GE-24V
24-port 10/100/1000Base-T chassis
with 4 SFP ports, 2 modular slots,
1AC+ 1 DC power supply, FTOS software
S50-01-GE-48T-V-2
48-port 10/100/1000Base-T chassis with
PoE, 4 SFP ports, 2 modular slots, 1AC+ 1
DC power supply, FTOS software
S50-01-10GE-2P
2-port 10 GbE XFP module
S50-01-10GE-2C
2-port 10 GbE CX4 module
S50-01-12G-2S
2-port 12 Gbps stacking module
S50-01-24G-1S
1-port 24 Gbps stacking module
S50-01-SSC-12G
60 cm stacking cable for S50-01-12G-2S
S50-01-LSC-12G
4 m stacking cable for S50-01-12G-2S
S50-01-SSC-24G
60 cm stacking cable for S50-01-24G-1S
S50-01-LSC-24G
4 m stacking cable for S50-01-24G-1S
S50-01-PSU-V
S25V/S50V redundant power supply unit
SW-SB-LATEST
Layer 3 FTOS software upgrade
Physical
S25N: 24 line-rate 10/100/1000Base-T ports
S50N: 48 line-rate 10/100/1000Base-T ports
4 SFP ports (shared)
1 RJ45 console/management port with RS232 signaling
Optional modules:
2 line-rate ports 10 Gigabit Ethernet XFP
2 line-rate ports 10 Gigabit Ethernet CX4
2 line-rate ports 12 Gigabit Stacking
1 line-rate port 24 Gigabit Stacking
Size: 1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d)
Weight: 15.62 lbs (7.10 kg)
ISO 7779 A-weighted sound pressure level:
S25V: 42.9 dBA at 73.4°F (23°C), S50V: 62.2 dBA at 73.4°F (23°C)
Power supply: 100–240 VAC 50/60 Hz, –48 VDC
Max. thermal output: S25V: 349 BTU/h, S50V: 497 BTU/h
Max. current draw per System:
6.5 A at 100/120 VAC, 3.25 A at 200/240 VAC, 11.5 A at -48 VDC
Max. current draw per system:
2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC
Max. power consumption:
S25V: 102 W, S50V: 146 W
Max. PoE power:
320 W using either AC or DC inputs
790 W using load sharing AC and DC inputs
Max. operating specifications:
Operating temperature: 32°to 122°F (0°to 50°C)
Operating humidity: 10 to 85% (RH), non-condensing
Max. non-operating specifications:
Storage temperature: –40°to 158°F (–40°to 70°C)
Storage temperature: –40°to 158°F (–40°to 70°C)
Reliability: S25V: MTBF 107,720 hours, S50V: MTBF 130,482 hours
Redundancy
Ring stacking topology with dynamic master election
Dual modular slots with up to four 10 GbE ports
Link aggregation across stack members
Power redundancy
Performance
MAC addresses:
S25N: 16K, 50V: 32K
IPv4 routes:
4K
IPv6 routes:
2,500
Switching fabric capacity:
S25V: 144 Gbps, S50V: 288 Gbps
User traffic capacity:
S25V: 128 Gbps (95 Mpps)
S50V: 176 Gbps (131 Mpps)
Link aggregation:
8 links per group, 128 groups per stack
Stacking capacity:
96 Gbps per stack member
Queues per port:
4 queues
VLANs:
1024 VLANs with 4096 tag value support
Line-rate Layer 2 switching:
all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing:
IPv4 and IPv6
LAG load balancing:
based on Layer 2, IPv4 or IPv6 headers
Switching latency:
<5 µs for 64 byte frames
IEEE Compliance
802.1AB
LLDP
802.1ag
Connectivity Fault Management
© 2011 Dell Inc. All rights reserved. Force10 Networks, Adit, E-Series, Traverse, and TraverseEdge are registered trademarks and Axxius, C-Series, ExaScale, FTOS, MASTERseries,
PowerSmart, P-Series, S-Series, TeraScale, TransAccess, VirtualScale, and VirtualView are trademarks of Dell Inc. All other company names are trademarks of their respective
holders. Information in this document is subject to change without notice. Dell Inc. assumes no responsibility for any errors that may appear in this document.
Learn more at Dell.com/Networking
SS794_Dell_Force10_Switch_25V_50V_092311
802.1D
Bridging, STP
802.1p
L2 Prioritization
802.1Q
VLAN Tagging, Double VLAN Tagging, GVRP
802.1s
MSTP
802.1w
RSTP
802.1X
Network Access Control
802.3ab
Gigabit Ethernet (1000BASE-T)
802.3ac
Frame Extensions for VLAN Tagging
802.3ad
Link Aggregation with LACP
802.3ae
10 Gigabit Ethernet (10GBASE-X)
802.3ak
10 Gigabit Ethernet (10GBASE-CX4)
802.3i
Ethernet (10BASE-T)
802.3u
Fast Ethernet (100BASE-TX)
802.3x
Flow Control
802.3z
Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057
LLDP-MED
Force10
FRRP (Force10 Redundant Ring Protocol)
Force10
PVST+
MTU
9,252 bytes
RFC and I-D Compliance
General Internet Protocols
768
UDP
1321
793
TCP
1350
854
Telnet
2474
959
FTP
3164
General IPv4 Protocols
791
IPv4
1812
792
ICMP
1858
826
ARP
2131
1027
Proxy ARP
2338
1035
DNS (client)
3021
1042
Ethernet Transmission
3046
1191
Path MTU Discovery
3069
1305
NTPv3
3128
1519
CIDR
1542
BOOTP (relay)
General IPv6 Protocols
1981
Path MTU Discovery
2463
(partial)
1858
2460
IPv6
2675
2461
Neighbor Discovery
3587
(partial)
2462
Stateless Address
4291
Autoconfiguration
(partial)
RIP
1058
RIPv1
2453
OSPF
2154
MD5
3623
1587
NSSA
4222
2328
OSPFv2
2370
Opaque LSA
BGP
1997
Communities
2918
2385
MD5
3065
2439
Route Flap Damping
4360
2796
Route Reflection
4893
2842
Capabilities
5396
2858
Multiprotocol Extensions
draft-ietf-idr-bgp4-20
BGPv4
draft-ietf-idr-restart-06
Graceful Restart
Multicast
1112
IGMPv1
2236
IGMPv2
3376
IGMPv3
3569
SSM for IPv4
4541
IGMPv1/v2 Snooping
draft-ietf-pim-sm-v2-new-05
PIM-SM
Network Management
1155
SMIv1
1156
Internet MIB
1157
SNMPv1
1212
Concise MIB Definitions
1215
SNMP Traps
1493
Bridges MIB
1850
OSPFv2 MIB
1901
Community-based SNMPv2
2011
IP MIB
2012
TCP MIB
2013
UDP MIB
2096
IP Forwarding Table MIB
2570
SNMPv3
2571
Management Frameworks
2572
Message Processing and Dispatching
2574
SNMPv3 USM
2575
SNMPv3 VACM
2576
Coexistence Between SNMPv1/v2/v3
2578
SMIv2
2579
Textual Conventions for SMIv2
2580
Conformance Statements for SMIv2
2618
RADIUS Authentication MIB
2665
Ethernet-like Interfaces MIB
2674
Extended Bridge MIB
2787
VRRP MIB
2819
RMON MIB (groups 1, 2, 3, 9)
2863
Interfaces MIB
2865
RADIUS
3273
RMON High Capacity MIB
3416
SNMPv2
3418
SNMP MIB
3434
RMON High Capacity Alarm MIB
MD5
3580
802.1X with RADIUS
TFTP
5060
PIM MIB
Differentiated Services
ANSI/TIA-1057
Syslog
draft-grant-tacacs-02
draft-ietf-idr-bgp4-mib-06
IEEE 802.1AB
Routers
IEEE 802.1AB
IP Fragment Filtering
IEEE 802.1AB
DHCP (relay)
ruzin-mstp-mib-02
VRRP
sFlow.org
31-bit Prefixes
sFlow.org
DHCP Option 82
FORCE10-BGP4-V2-MIB
Private VLAN
Tiny Fragment Attack
FORCE10-IF-EXTENSION-MIB
Protection
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
ICMPv6
FORCE10-SS-CHASSIS-MIB
IP Fragment Filtering
FORCE10-SMI
Jumbograms
FORCE10-SYSTEM-COMPONENT-MIB
Global Unicast
FORCE10-TC-MIB
Address Format
FORCE10-TRAP-ALARM-MIB
Addressing
Regulatory Compliance
Safety
UL/CSA 60950-1, 1st Edition
RIPv2
EN 60950-1, 1st Edition
IEC 60950-1, 1st Edition Including all National Deviations
and Group Differences
Graceful Restart
Prioritization and
EN 60825-1 Safety of Laser Products Part 1: Equipment
Congestion Avoidance
Classification Requirements and User's Guide
EN 60825-2 Safety of Laser Products Part 2:
Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Route Refresh
Emissions
Confederations
Extended Communities
Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
Canada: ICES-003, Issue-4, Class A
4-byte ASN
Europe: EN 55022: 2006+A1:2007 (CISPR 22: 2006), Class A
4-byte ASN
Japan: VCCI V3/2009 Class A
Representation
USA: FCC CFR 47 Part 15, Subpart B:2009, Class A
Immunity
EN 300 386 V1.4.1:2008 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS
All S-Series components are EU RoHS compliant
The features and specifications are for FTOS. For SFTOS features
and specifications, please refer to the SFTOS data sheet..
LLDP-MED MIB
TACACS+
BGP MIBv1
LLDP MIB
LLDP DOT1 MIB
LLDP DOT3 MIB
MSTP MIB (traps)
sFlowv5
sFlowv5 MIB (version 1.3)
Force10 BGP MIB
(draft-ietf-idr-bgp4-mibv2-05)