Dell S6010-ON Installation Manual - Page 31

Browse online or download pdf Installation Manual for Switch Dell S6010-ON. Dell S6010-ON 46 pages.
Also for Dell S6010-ON: Firmware Release Notes (12 pages)

Dell S6010-ON Installation Manual
Figure 18. S6010–ON AC power supply installation
1
1–PSU
When you install the PSU correctly, it snaps into place and is flushed with the back of the switch.
4
Plug in the appropriate three-prong AC power cord from the switch PSU to the external power source.
5
Repeat steps 1 through 4 using the second PSU slot if you have a redundant PSU.
NOTE:
The S6010–ON powers up when you connect the cables between the power supply and the power source.

AC power supply replacement

CAUTION:
Disconnect the power cord before removing the power supplies. Also, disconnect all power cords before servicing.
NOTE:
The PSU slides into the slot smoothly. Do not force a PSU into a slot as this action may damage the PSU or the S6010–
ON chassis.
NOTE:
If a PSU fails, replace the entire unit. There are no field serviceable components in the PSU. To request a hardware
replacement, see
Dell
NOTE:
If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1 (PSU1) as the
blank plate slot.
1
Disconnect the power cable from the PSU.
2
Use the grab handle to slide the PSU out of the power supply bay.
3
Use the grab handle on the replacement PSU to slide it into the power supply bay.
4
Attach the power cord to the replacement PSU.
NOTE:
The system powers up when you connect the cables between the power supply and the power source.

DC power supply connection

Each sold-separately DC PSU kit comes with a connector cable.
Support.
2
2–PSU slot
Power supplies
31