LED behavior
The following system LED behavior is seen during open networking installation environment (ONIE) operations:
Figure 5. S6010–ON I/O side LEDs
1
Master LED
3
Locator LED
5
QSFP+ LEDs
7
Management Port Link LED
9
Power LED
Table 1. S6010–ON I/O-side LED behavior
LED
Master
Status
Locator
QSFP+ port when used as one 40G port. Only the first LED is used
in 40G mode.
2
Status LED
4
RS–232/RJ-45 Serial Console Port LED
6
Stack ID LED
8
Fan LED
Description
•
Off—switch is in stacking slave mode
•
Solid green—system is in stacking master or standalone mode
•
Solid green—normal operation
•
Blinking green—booting
•
Solid amber—critical system error
•
Blinking amber—noncritical system error—fan failure or power
supply failure
•
Off—locator function is disabled
•
Blinking blue—locator function is enabled
•
Off—No Link
•
Solid green—link at 40G speed
•
Blinking green—port activity at 40G speed
•
Solid amber—link at speed lower than 40G
•
Blinking amber—port activity at lower than 40G speed
S6010–ON System