Acquiring images
Troubleshooting
To find solutions for unexpected events, see Chapter Troubleshooting in the Mako U Technical
Manual.
1.
Connect your USB camera to your PC via USB 3.0 cable.
2.
Start Vimba Viewer. For instructions on Vimba Viewer, see Vimba Quickstart Guide provided with the Vimba
download.
3.
Select the camera in Vimba Viewer.
The main window opens.
4.
Start acquisition to acquire the first images with your USB camera.
Using third-party software
Using the camera with third-party software
Allied Vision USB cameras comply with USB3 Vision V1.0.1 standard. They can be used with
every third-party software that complies with the USB3 Vision standard.
Camera I/Os and LEDs
1
6
2
5
3
4
Pin
Line
Signal
1
0
GPIO 1
non-isolated, programmable
2
1
GPIO 2
non-isolated, programmable
3
2
In 1
opto-isolated
4
3
Out 1
opto-isolated, open collector
5
---
Isolated GND for isolated I/O
6
---
GND for GPIOs
LED signal pattern
Status
Camera startup
Power on
Command or image traffic
Camera busy
Standards conformity
CE, RoHS
Contacting Allied Vision
For ordering and general information
https://www.alliedvision.com/contact
Support
3
6-pin I/O connector
Status LED (red)
Status LED (green)
<->
Level
I/O
U
(low) = 0 to 0.8 VDC
in
U
(high) = 2 to 24 VDC
in
U
(low) = 0 to 1.0 VDC
out
U
(high) = 3.3 to 24 VDC @ max. 25 mA (open collector)
out
I/O
U
(low) = 0 to 0.8 VDC
in
U
(high) = 2 to 24 VDC
in
U
(low) = 0 to 1.0 VDC
out
U
(high) = 3.3 to 24 VDC @ max. 25 mA (open collector)
out
In
U
(low) = 0 to 1.0 VDC
in
U
(high) = 3 to 24 VDC
in
Out U
(low) = 0.3 to 2 VDC
out
U
(high) = 3 to 24 VDC @ max. 25 mA (open collector)
out
---
---
---
---