8. Instructions for Manta cameras – RCG
At delivery, sensors of RCG cameras are protected by the circular protection foil placed on the lens mount.
This section instructs on removing the circular protection foil and mounting the lens.
Damage to the camera electronics and sensor
• Work in a dust-free environment (class 100 or better) with humidity according
• Observe notes for
• Follow the instructions thoroughly.
1. With your finger tips, starting from the edge, slowly pull the circular protection foil from the lens mount
until removed completely.
Lens mount
Adhesive
Foil egde
Figure 7: Pulling the circular protection foil off the lens mount
Damage to the sensor
If you want to use your camera without lens, observe
Damage to sensor and lens
If the lens exceeds maximum protrusion, camera or lens may be damaged.
• To avoid damaging the sensor or the back lens, use lenses with a maximum
2. Mount your optics according to the manual of the lens manufacturer and the Manta User Guide.
Without compensation, cameras could be focused to infinity after the sensor cover glass has been
removed. Therefore, Manta RCG cameras are calibrated for proper focus before shipping.
to ESD requirements.
3.1. Electrostatic discharge (ESD)
protrusion within camera specifications. For details, see your camera's user
guide.
Page 7 of 18
Preparing Cameras without
NOTICE
on page 1.
NOTICE
3. Safety notes
NOTICE
Sensor Cover Glass
on page 1.