Name
Holding Registers (read-write register addresses, read function byte 0x03, write function byte 0x06 for single or
0x10 for multiple registers)
K-Factor
Max Flowrate
Flow Rate Time Base
Flow Rate Volume Unit
Max Flow Time Base
Max Flow Volume Unit
Input Registers (read-only register addresses, read function byte 0x04)
Raw Frequency Input
Flow Rate (Users units)
EDGE Sensor Modbus Registers
Register Start
Register
Address
Count
3000
3002
4000
4001
4002
4003
5000
5002
Value
type
2
32 Bit Float
2
32 Bit Float
1
Int
1
Int
1
Int
1
Int
2
32 Bit Float
2
32 Bit Float
Value
Units/Description
0- Seconds
1- Minutes
2- Hours
3- Days
0- Pulses
1- Ounces
2- Gallons
3- Barrels (Oil)
4- Cubic Centimeters
5-Cubic Meters
6- Mili-Liters
7- Liters
0- Seconds
1- Minutes
2- Hours
3- Days
0- Pulses
1- Ounces
2- Gallons
3- Barrels (Oil)
4- Cubic Centimeters
5-Cubic Meters
6- Mili-Liters
7- Liters
(Hz)
17 |