360 Y-DROP Replacement Instructions - Page 2

Browse online or download pdf Replacement Instructions for Industrial Equipment 360 Y-DROP. 360 Y-DROP 2 pages. Breakaway magnet

BREAKAWAY MAGNET
REPLACEMENT INSTRUCTIONS
STEP 1
REMOVE OLD MAGNET
1
3
Trip the breakaway and insert a stop block 1 to hold the
breakaway open.
Remove the riser tube 2. Keep pin and rise tube as these
will be reinstalled at the completion of the magment
replacement.
Clamp magnet body with vice grips 3.
Using an impact, remove screw 4 from the magnet body.
Discard the magnet, magnet body, washer and screw.
STEP 2
INSTALL REPLACEMENT MAGNET
7
2
6
4
Slide new washer 5 onto the new screw 6.
Apply a drop of threadlocker 7 to the screw.
Place the new magnet 8 into the rubber grommet 9 on
the inside of the breakaway.
Install the screw and washer
Use hand screw driver to tighten only to the point that the
magent spins.
Reinstall the riser tube and secure with pin
5
9
10
8
11
into the magnet body.
10
11
.
PAGE 2
REPLACEMENT COMPLETE