Allied Vision Prosilica GT Manual - Page 10
Browse online or download pdf Manual for Accessories Allied Vision Prosilica GT. Allied Vision Prosilica GT 18 pages.
9.2. Disassembling Prosilica GT Large Format housing cameras
1. Power off and unplug the camera.
2. Loosen and remove the four M2 x 10 socket head cap screws of the front assembly.
Figure 13: Removing the four M2 x 10 socket head cap screws of the front assembly
3. Flip the front assembly (c) by approximately 45° to the right side of the body assembly (d).
For the next steps, avoid mechanical stress to the ribbon cable (a).
The ribbon cable is included only for cameras with certain mount options.
4. Disengage the flexible contact bar (b).
Camera top
Figure 14: Flipping front assembly away from the body assembly
5. Continue to flip open the front assembly to an angle of 180° and position the sections next to each
other on the workbench
Continuing the disassembly
• Keep the camera flipped open as described in step
• The illustrations of the next action steps are schematics.
a
d
Page 10 of 18
Preparing Cameras without
Sensor Cover Glass
b
Lens mount
c
5.