Miele PW 5105 EL Installations Plan - Page 11

Browse online or download pdf Installations Plan for Washer Miele PW 5105 EL. Miele PW 5105 EL 13 pages.
Also for Miele PW 5105 EL: Installations Plan (16 pages)

Miele PW 5105 EL Installations Plan
Technical datasheet
Washer-extractor:
Heating:
Legend:

Optional extras:

Miele base
UO 5010 (UO = open base)
UM
Height
Width
Depth
UG 5010 (UG = closed base)
Height
Width
Depth
Concrete base
Quality and density of concrete must comply with load.
BS
Concrete base must be firmly secured to floor!
Recommended height
Minimum height
Recommended width
Recommended depth
Dispensing
Pump installation may only be performed by Miele Service.
pump
External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Fusing
Supplied with supply cable and plug
Machine connections:
Electrical
connection
(convertible)
Electrical connection must comply with national regulations.
Connection using multi-pole wall lockable socket in compli-ance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests. If machines are hard-wired, a multi-pole mains switch must be
provided on site. Switches with a contact gap of more than 3 mm can be used. These include switches, fuses and
contactors (IEC/EN 60947). A wall socket or mains isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment or checks on the protective conductor, including
determination of correct fuse rating, should only be performed by a properly trained electrician.
If necessary, equipotential bonding with good galvanic contact must be provided in accordance with all
appropriate national and local regulations.
Technical datasheet: PW5105 EL AV (Dump valve)
Date: 01.2015
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Standard voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supplied with plug
Convertible to
Frequency
Rated load
Fuse rating
Length of supply lead
Supplied with plug
PW 5105 AV (Dump valve)
Electric (EL)
en - US
12''
305 mm
27''
684 mm
31''
787 mm
12''
305 mm
27 1/4''
692 mm
31''
788 mm
11 13/16''
300 mm
2 3/4''
70 mm
≥ 27 9/16''
≥700 mm
≥ 31 1/2''
≥800 mm
120V
15A
NEMA 5-15
2 AC 220 - 240V
60 Hz
4.4 - 5.2 kW
2 x 30 A
6.5'
2000 mm NEMA
L6-30P
2 AC 208V
60 Hz
4.0 kW
2 x 30 A
6.5'
2000 mm NEMA
L6-30P