SERIAL NUMBER 14-000001 AND UP
Burner starts to smoke and build black smoke out of exhaust stack:
** Black smoke is an indication the unit is not getting enough air, bad fuel or carbon build up in
the chamber.**
❏ Make sure air setting is on a specified number that the IQ controller
recommends at the time of start up. D O NOT adjust air setting during
operation unless the IQ controller specifies. (Any change of ambient
temperature and elevation requires smaller or higher amounts of air
mixture.)
❏ Check for any debris or material covering or blocking the air damper.
Clean and clear.
❏ Check fuel pressure and maintain 140-145 PSI at the pump.
❏ Ensure fuel nozzle NO 1 & NO 2 are both clean and working correctly.
Check the schematic for a list of wiring for each nozzle. IQ logic controls
both nozzles to maintain temperature.
❏ Make sure the heat exchanger and burn chamber are clear of any soot
build up. If there is a large amount of build up then take the burner apart
and wash with hot water high pressure hose. Let the barrel air dry before
using.
❏ Make sure only NO 1 Diesel fuel is used. Any additives can cause more
gel-like substances which will create fuel issues.